TECHNICAL DATA
Solution 5 kW
Widescreen
S4
Solution 7 kW
S4
Nominal Heat Output—Wood (kW) 5.0 7.0
Efficiency Nett At Nominal Heat
Output (%) 82.5 77.9
Mean Flue Gas Temperature (°C) 240 291
Mean CO Emission @ 13% O2 (%) 0.12 0.12
Flue Mass Gas Flow (g/s) 4.0 6.2
Typical Fuel Load To Achieve
Nominal Rated Output Per Hour
(Kwh/Kg) (Seasoned Hardwood) 1.17 1.55
Mean CH Emission @ 13% O2 (%) 113 107
Mean NOx Emission @ 13% O2(%) 84 109
DIN Plus Particulates @ 13% O2 13 18
Ideal Log Length & Diameter (mm) 330 / 100 330 / 100
Nominal Heat Output—Solid Fuel
(kW) 5.0 7.1
Efficiency Nett At Nominal Heat
Output (%) 79.4 81.5
Mean Flue Gas Temperature (°C) 291 326
Mean CO Emission @ 13% O2 (%) 0.05 0.06
Flue Mass Gas Flow (g/s) 3.3 4.3
Typical Fuel Load To Achieve
Nominal Rated Output Per Hour
(Kwh/Kg) (MSF Maxibrite) 0.73 1.0
Mean CH Emission @ 13% O2 (%) 30 42
Mean NOx Emission @ 13% O2
(%) 121 120
DIN Plus Particulates @ 13% O2
(%) 25 24