Remaining Dangers and Protection Measures
Electric Remaining Dangers
Danger
Description
Protection Measures
Direct
electric
contact
Electric shock
Insufficient current switch FI
Indirect
electric
contact
Electric shock
via the medium
Insufficient current switch FI
Disposal
Disposal instructions are illustrated in the form of pictograms
on the device or packaging. Description of the pictograms is
given in "Identification" chapter.
Disposal of transport packaging
Packaging protects the device against damage during
transport. Packaging materials are usually selected according
to their effect on environment and disposal methods and can
therefore be recycled.
Returning of the packaging back to circulation saves
resources and costs for packaging disposal.
Parts of the packaging (e.g. foil, styropor) may be dangerous
for children. Risk of suffocation!
Keep these parts of the packaging out of reach of children
and dispose as soon as possible.
The Requirements on the Operator
The Operator shall carefully read the Operation Manual
before using the device.
Qualification
The professionaly versed person does not need any special
qualification for using the device.
Minimum Age
The devfice may only be operated by persons at the age of 16
and more. The exception is using the device by an adolescent
in the course of his training for the profession, where the
device is used for the purpose of getting the skill under
supervision of the instructor.
Training
The operator who is going to operate the device will only need
to get corresponding training by a professionally trained
person, and/or a training according to the Operation Manual.
No special training is necessary.
Technical data
HWW 1300 G
Supply main
230 V / 50 Hz
Engine P1 output
1300 W
Max. suction height
7,5 m
Max. pumped quantity
4000 l/min
Max. pumping height
48 m
Pressure supply main
1“
Suction supply main
1’’
Way of protection
IP X4
Water temperature
35 °C
Vessel
24 l
Weight approx.
19,6 kg
Assortment position No.
94195
Transport and Storing
When storing in winter, make sure that no water is in
the device, otherwise the device may be destroyed due to
freezing.
Assembly and First Putting into Operation
Filter and Screen for Impurities
If the water contains sand, the pump shall be operated with
the filter for impurities (available as accessory) located on the
suction supply main of the pump. Should the sand penetrate
into the friction circle sealing (connecting shift pump) the
sealing would be destroyed. If this occurs in the course of
guarantee term, it will be qualified as a fault caused by the
user and this case will be excluded from any provision of
guarantee.
Safety Instructions for First Putting into Operation
Caution: The pump shall never be operated without
water.
When using the pump (water equipment) the user is
responsible to third persons
The user may operate the pump only on connecting lines
furnished with the insufficient current switch (FI switch)!
Before putting into operation the authorized electrician should
check if there are required electric safety measures available.
The electric connection shall be performed by means of a
socket.
Voltage examination. Technical data on the label shall comply
with the electric network voltage.
If the pump is used for ponds, wells etc. and in corresponding
water equipments, the standards applicable in the countries where
the pump is used shall be unconditionally observed.
Electric pumps used outside (e.g. at the ponds etc.) shall be
furnished with rubber electric cable type H07RNF, according to
standard DIN 57282 or. DIN 57245.
When the pump is in operation, no people or animals are
allowed to stay in the liquid being repumped (e.g. in
swimming pools, in cellars etc.).
The repumped liquid temperature shall not exceed +35 °C.
Should extension cables be used, they shall be made
exclusively of rubber, type H07RNF, according to standard
DIN 57282 or DIN 57245. The pump connected to the
electric network shall never be touched by a cable, never
lifted by holding the cable or transport by means of a cable.
The connecting socket shall always be in necessary
distance from water and moisture and the plug shall be
protected against moisture.
Before putting the pump into operation check if the electric
cable and/or the socket are not damaged.
Before performance of any works on the pump the plug
shall be pulled out of the socket..
If the pump is built-in in a gully, the gully shall be covered
with cover to ensure the safety of people walking there.
The pump shall never be installed in moist shifts
(danger of shortcut, damage caused by corrosion)!
For avoiding or prevention of possible damage (as e.g.
flooding the rooms etc.) due to faulty pump operation
(e.g. due failure or defects) the owner (user) shall take
reasonable safety measures (installation of alarm
equipment, a spare pump etc.)
In case of failure on the pump,. the repair shall be
performed exclusively by an authorized service
repairshop.Only original spare parts may be used.
We have to draw your attention to the fact that
according to the valid standards we cannot take
11
11

Hulp nodig? Stel uw vraag in het forum

Spelregels
1

Forum

Gude-HWW-1300-G-94195

Zoeken resetten

  • Pomp komt niet op druk.
    Druk wordt niet hoger dan 3bar,dus de pomp blijft doorlopen maar slaat niet af
    Wat is de oorzaak? Gesteld op 11-8-2022 om 15:53

    Reageer op deze vraag Misbruik melden

Misbruik melden

Gebruikershandleiding.com neemt misbruik van zijn services uitermate serieus. U kunt hieronder aangeven waarom deze vraag ongepast is. Wij controleren de vraag en zonodig wordt deze verwijderd.

Product:

Bijvoorbeeld antisemitische inhoud, racistische inhoud, of materiaal dat gewelddadige fysieke handelingen tot gevolg kan hebben.

Bijvoorbeeld een creditcardnummer, een persoonlijk identificatienummer, of een geheim adres. E-mailadressen en volledige namen worden niet als privégegevens beschouwd.

Spelregels forum

Om tot zinvolle vragen te komen hanteren wij de volgende spelregels:

Belangrijk! Als er een antwoord wordt gegeven op uw vraag, dan is het voor de gever van het antwoord nuttig om te weten als u er wel (of niet) mee geholpen bent! Wij vragen u dus ook te reageren op een antwoord.

Belangrijk! Antwoorden worden ook per e-mail naar abonnees gestuurd. Laat uw emailadres achter op deze site, zodat u op de hoogte blijft. U krijgt dan ook andere vragen en antwoorden te zien.

Abonneren

Abonneer u voor het ontvangen van emails voor uw Gude HWW 1300 G 94195 bij:


U ontvangt een email met instructies om u voor één of beide opties in te schrijven.


Ontvang uw handleiding per email

Vul uw emailadres in en ontvang de handleiding van Gude HWW 1300 G 94195 in de taal/talen: Nederlands, Duits, Engels, Frans, Italiaans als bijlage per email.

De handleiding is 2,33 mb groot.

 

U ontvangt de handleiding per email binnen enkele minuten. Als u geen email heeft ontvangen, dan heeft u waarschijnlijk een verkeerd emailadres ingevuld of is uw mailbox te vol. Daarnaast kan het zijn dat uw internetprovider een maximum heeft aan de grootte per email. Omdat hier een handleiding wordt meegestuurd, kan het voorkomen dat de email groter is dan toegestaan bij uw provider.

Stel vragen via chat aan uw handleiding

Stel uw vraag over deze PDF

loading

Uw handleiding is per email verstuurd. Controleer uw email

Als u niet binnen een kwartier uw email met handleiding ontvangen heeft, kan het zijn dat u een verkeerd emailadres heeft ingevuld of dat uw emailprovider een maximum grootte per email heeft ingesteld die kleiner is dan de grootte van de handleiding.

Er is een email naar u verstuurd om uw inschrijving definitief te maken.

Controleer uw email en volg de aanwijzingen op om uw inschrijving definitief te maken

U heeft geen emailadres opgegeven

Als u de handleiding per email wilt ontvangen, vul dan een geldig emailadres in.

Uw vraag is op deze pagina toegevoegd

Wilt u een email ontvangen bij een antwoord en/of nieuwe vragen? Vul dan hier uw emailadres in.



Info