Being closed all the doors of the vehicle, turn the ignition key to “ON”; after 20”,
all doors will be locked.
By turning the ignition key to “OFF”, all doors of the vehicle will be automatically
unlocked.
After programming, this function is obtained simply by turning the ignition key
to “OFF”.
When opening a vehicle's door during passive arming, the arming time count
will be set to zero and the led will be permanently illuminated; when the door is
closed the 45” counting will restart.
LOCKING TIME
The standard locking time of the alarm is set to 0,5”.
In case the vehicle needs a locking time of 6”, you can vary this parameter
during the programming phase.
NOTE: When the comfort function has been activated, let the locking time set
to 0,5”.
In fact, if the locking time is set to 6”, when the alarm is disarmed, the windows
of the vehicle will open.
COMFORT CONTROL
The comfort control allows the automatic regulation of window closing, when
the alarm is armed.
In fact, after this function has been activated, at any alarm arming, the window
winder motor/control unit will receive a 25” command, to close the windows.
To prevent this function from being activated accidentally, the system
continuously monitors the status of the ignition key and the input line of the
DOOR AND BOOT PUSHBUTTONS and therefore does not allow operation of
the locks if the DOORS and BOOT are opened manually while starting the
engine or during the 20” after starting it.
PASSIVE ARMING
Automatic arming allows to have the alarm system active, 45 seconds after the
engine switching “OFF”.
The alarm will indicate the passive arming activation by a long flash of the turn
signals, two flash of the status led and two acoustic signals.
CDL DOUBLE OPENING PULSE
By enabling this function you will obtain, upon deactivation of the system, a
double control pulse on the door-unlocking line (about 0,5 second each).
This allows the opening of the centralized door locks on vehicles having the
diversified door opening (first pulse driver side door opening, second pulse
other doors opening).
This function is active only if the opening/closing time of 0,5” is selected, while
setting the opening/closing timo of 6” will automatically disabled the double
pulse.
PROGRAMMING THE ALARM SYSTEM
Has been previously programmed with standard configuration during
manufacturing procedure by Gemini, and can be modified in any moment
! With alarm being disarmed, open and keep it open the driver side door.
! Turn the ignition key to "ON" position.
! The status led stay on for 0,5 seconds; during this time, push together the
two buttons of the remote control.
! Starting of programming procedure is indicated by two acoustic signals,
one with high tone and one with loud tones, furthermore the led is
permanently illuminated.
! To able and disable the functions, follow the below table, take into
consideration that every time the push button of transmitter is pressed, the
system goes to the following function.
During the programming phases, press the radio control (rough) push-button
n.1, for function activation and the (smooth) push-button n.2, for function de-
activation.
ATTENTION: pay attention to not modify the functions which have been
programmed during the installation.
For the programming modification proceed as follows:
NOTE:
Once the last function has been programmed, the alarm will confirm that
the programming has been disabled with two acoustic signals with low
tone, one acoustic signal with high tone,
! Turn the ignition key to “OFF” position.
by turning the ignition key to
OFF”, in any moment of the programming
procedure, the latter will stop and successive functions will remain unchanged.
!
furthermore the led will be turned
off.
Acoustic signals
Panic alarm or “car finder”
Passive arming
Current absorption sensor
Anti-distraction, automatic
door locking function
Setting of centralized lock
times (0,5 - 6 sec)
25 seconds comfort closure
command
Double impulse in opening
Enabled
Enabled panic
alarm
Disabled
Disabled
Disabled
0,5” selected
Disabled
Disabled
Button N°1- Enable
N°2- Disable
N°1- Enable panic
N°2- Enable
N°1-
N°2-
N°1-
N°2-
Button
Button
Button car-finder
Button Enable
Button Disable
Button N°1- Enable
Button N°2- Disable
Button Enable
Button Disable
Button N°1- Enable 6”
Button N°2- Enable 0,5”
Button N°1- Enable
Button N°2- Disable
Button N°1- Abilita
Button N°2- Disable
FUNCTION
STATE BUTTON
4

Hulp nodig? Stel uw vraag in het forum

Spelregels

Misbruik melden

Gebruikershandleiding.com neemt misbruik van zijn services uitermate serieus. U kunt hieronder aangeven waarom deze vraag ongepast is. Wij controleren de vraag en zonodig wordt deze verwijderd.

Product:

Bijvoorbeeld antisemitische inhoud, racistische inhoud, of materiaal dat gewelddadige fysieke handelingen tot gevolg kan hebben.

Bijvoorbeeld een creditcardnummer, een persoonlijk identificatienummer, of een geheim adres. E-mailadressen en volledige namen worden niet als privégegevens beschouwd.

Spelregels forum

Om tot zinvolle vragen te komen hanteren wij de volgende spelregels:

Belangrijk! Als er een antwoord wordt gegeven op uw vraag, dan is het voor de gever van het antwoord nuttig om te weten als u er wel (of niet) mee geholpen bent! Wij vragen u dus ook te reageren op een antwoord.

Belangrijk! Antwoorden worden ook per e-mail naar abonnees gestuurd. Laat uw emailadres achter op deze site, zodat u op de hoogte blijft. U krijgt dan ook andere vragen en antwoorden te zien.

Abonneren

Abonneer u voor het ontvangen van emails voor uw Gemini 7562 bij:


U ontvangt een email met instructies om u voor één of beide opties in te schrijven.


Ontvang uw handleiding per email

Vul uw emailadres in en ontvang de handleiding van Gemini 7562 in de taal/talen: Engels als bijlage per email.

De handleiding is 0,27 mb groot.

 

U ontvangt de handleiding per email binnen enkele minuten. Als u geen email heeft ontvangen, dan heeft u waarschijnlijk een verkeerd emailadres ingevuld of is uw mailbox te vol. Daarnaast kan het zijn dat uw internetprovider een maximum heeft aan de grootte per email. Omdat hier een handleiding wordt meegestuurd, kan het voorkomen dat de email groter is dan toegestaan bij uw provider.

Stel vragen via chat aan uw handleiding

Stel uw vraag over deze PDF

loading

Uw handleiding is per email verstuurd. Controleer uw email

Als u niet binnen een kwartier uw email met handleiding ontvangen heeft, kan het zijn dat u een verkeerd emailadres heeft ingevuld of dat uw emailprovider een maximum grootte per email heeft ingesteld die kleiner is dan de grootte van de handleiding.

Er is een email naar u verstuurd om uw inschrijving definitief te maken.

Controleer uw email en volg de aanwijzingen op om uw inschrijving definitief te maken

U heeft geen emailadres opgegeven

Als u de handleiding per email wilt ontvangen, vul dan een geldig emailadres in.

Uw vraag is op deze pagina toegevoegd

Wilt u een email ontvangen bij een antwoord en/of nieuwe vragen? Vul dan hier uw emailadres in.



Info