10
6.2 Electrical connection
Rated power consumption: 3.0 kW
You are advised to place a properly installed socket
outlet with earthing contact around 70 cm above
floor level behind the appliance.
Note:
if there is a need for an intermediate cupboard wall
under the hob, cut out the recess so that the trough
of the hob does not lie on the cupboard side wall
and so that a distance of 20 mm from the
intermediate cupboard wall is guaranteed.
Please note that a distance of 10 mm from the base
cabinet must be observed for safety reasons. (see
figure)
The mains connecting cable must at least
correspond to type H 05 V2V2 or it must be
correspondingly heat-resistant (at least 90 °C).
The mains connecting cable must only be
purchased through and connected by an
authorised specialist.
Pay attention to the information on the rating plate
and connect the PE conductor. Connect the
connecting cable to the mains.
Connection type Y: if damaged, the mains cable
must be replaced by a special mains connecting
cable. The mains connecting cable must only be
connected by the manufacturer or the manufac-
turer's after-sales service.
Note:
when installing a shelf, observe a distance of at
least 20 mm from the bottom edge of the housing
trough to the shelf or the next combustible item
of furnishing.
VC 230-112 FD xxx xxxxxxxxx
AC 230 V 50/60 Hz max. 3000 W
16 A
VC 230-512 FD xxx xxxxxxxxx
AC 240 V 50/60 Hz max. 3000 W
16 A