- 12 -
10. Specifications
Model : FC270211
Type of apparatus : Type B
Power Supply : DC 3V (2pcs alkaline battery)
Recommend battery type : GP GN15A / Raymax LR6
(For 3 years battery life at normal operation)
Sensor Type : Electrochemical
Product Life : 10 years after manufacture
Sensitivity Setting : Conforms to EN 50291-1:2018 standard.
030PPM Without alarm before 120 minutes
050PPM Between 60 to 90 minutes
100PPM Between 10 to 40 minutes
300PPM Less than 3 minutes
Standby Current : <20μA (average)
Alarm Current : <30mA (average)
Operation Ambient Condition : -10~+40℃, 30~95% non-condensing
Storage/Transport Ambient Condition : -20~+50℃, 10~95% non-condensing
Alarm Sound : ≥85DB at 3m @3.2±0.5KHz pulsing alarm
CO Alarm Silence : About 10 minutes
Other Warning Silence : About 9 hours
Installation Location : Ceiling or wall of domestic premises
Detection Range : Max. 40 m2 within a room
NOTE:
- This CO alarm is designed to detect carbon monoxide gas from any source of combustion.
It is not designed to detect any other gas.
11. Symbols
Recycling and Disposal: The WEEE symbol indicates that this product and its batteries must
be disposed of separately from household waste. When this product reaches the end of its
service life, take it to a designated waste collection point nearby to ensure safe disposal or
recycling. Protect the environment and human health, use natural resources responsibly!
Updates or new warmings might apply to the manual. Always check the most up to date
manual on www.elro.eu before installing or reinstalling the product. Read the manual
before use and keep it in a safe place for future use and maintenance.
Guarantee visit www.elro.eu
ELRO Europe | www.elro.eu
Postbus 9607 - Box E800
1006 GC Amsterdam - The Netherlands