Notice: Defective overload cut-outs must be
replaced only by overload cut-outs of identical
design and with the same performance data. If
repairs are necessary, please contact your
customer service center.
7. Cleaning, maintenance, storage and
ordering of spare parts
Switch off the motor and pull the spark plug boot
from the spark plug before doing any cleaning and
maintenance work on the equipment.
Notice: Switch off the machine immediately and
contact your service station:
앬 In the event of unusual vibrations or noise
앬 If the engine appears to be overloaded or
misfires
7.1 Cleaning
n Keep all safety devices, air vents and the motor
housing free of dirt and dust as far as possible.
Wipe the equipment with a clean cloth or blow it
with compressed air at low pressure.
n We recommend that you clean the device
immediately each time you have finished using it.
n Clean the equipment regularly with a moist cloth
and some soft soap. Do not use cleaning agents
or solvents; these could attack the plastic parts
of the equipment. Ensure that no water can seep
into the device.
7.2 Air filter
In this connection, please also read the service
information.
앬 Clean the air filter at regular intervals, and replace
it if necessary.
앬 Open both clips (Fig. 11/A) and remove the air
filter cover (Fig. 11/B).
앬 Remove the filter elements (Fig. 12/C)
앬 Do not use abrasive cleaning agents or petrol to
clean the elements.
앬 Clean the elements by tapping them on a flat
surface. In cases of stubborn dirt first clean with
soapy water, then rinse with clear water and air-
dry.
앬 Assemble in reverse order
7.3. Spark plug (Fig. 13-14)
Check the spark plug for dirt and grime after 20
hours of operation and if necessary clean with a
copper wire brush. Thereafter service the spark plug
after every 50 hours of operation.
앬 Pull off the spark plug boot with a twist.
앬 Remove the spark plug with the supplied spark
plug wrench.
앬 Assemble in reverse order
7.4 Changing the oil and checking the oil level
(before using the machine)
The motor oil is best changed when the motor is at
working temperature.
앬 Only use motor oil (15W40).
앬 Place the generator on a slightly inclined surface
so that the oil drain plug is at the lower end.
앬 Open the oil filler plug.
앬 Open the oil drain plug and let the hot engine oil
drain out into a drip tray.
앬 After the old oil has drained out, close the oil
drain plug and place the generator on a level
surface again
앬 Fill in engine oil up to the top mark on the oil dip
stick (approx. 0.6 liters).
앬 Important: Do not screw the dipstick in to check
the oil level, simply insert it up to the thread.
앬 Dispose of the waste oil properly.
7.5 Automatic oil cut-out
The automatic oil cut-out responds if there is too little
oil in the engine. In this case it will not be possible to
start the engine or it will cut out automatically after a
short period of time. It cannot be started again until
the engine oil has been topped up (see point 7.4).
7.6 Ordering replacement parts:
Please quote the following data when ordering
replacement parts:
n Type of machine
n Article number of the machine
n Identification number of the machine
n Replacement part number of the part required
For our latest prices and information please go to
www.isc-gmbh.info
8. Disposal and recycling
The unit is supplied in packaging to prevent its being
damaged in transit. This packaging is raw material
and can therefore be reused or can be returned to
the raw material system.
The unit and its accessories are made of various
types of material, such as metal and plastic.
Defective components must be disposed of as
special waste. Ask your dealer or your local council.
GB
15