10
D
S
GB
F
Wire harness connection, right or left
If necessary, the wire harness connection can also
be converted to the opposite side of the heater.
To this end, the control unit needs to be dismantled
and the bottom half-round wire harness covering
unclipped.
The wire harness can now be relayed in the control
unit.
Afterwards, reinstall the control unit, put on the shell
and while doing so, insert the wire harness bush and
the blind plug into the corresponding recesses in the
bottom shell.
Permissible mounting positions
The
AIRTRONIC
should preferably be installed in the
normal position - as indicated in drawing.
Depending on the installation conditions, the
AIRTRONIC
can be mounted according to diagram 1
at a slant of up to max. 30° (direction of flow
downwards!), or swivelled around its own longitudinal
axis through max. 90° (exhaust pipe vertical, glow
plug pointing upwards!). On account of the inclined
position of the vehicle or boat while travelling, during
heating operations the illustrated normal or maximum
positions can vary up to +15° in all directions without
impairing the functions of the heater.
햲 Hot air intake (impeller)
햳 Position of glow plug
햴 Direction of flow
Normal position horizontal (exhaust pipe to the
bottom) with permissible swivel range)