577319
5
Verklein
Vergroot
Pagina terug
1/27
Pagina verder
06/ 2014
TRITEST
®
pro
3
Operating Manual
TRITEST
®
pro
Before using the TRITEST
®
pro phase sequence
indicator:
Pleasereadtheoperatingmanualandabsolutely
observethesafetyinstructions!
Table of contents
1. Safetyinstructions
2. Device description
3. Functional test
4. Phase sequence test
5. LED torch
6. Batteryreplacement
7. Technical data
8. General maintenance
9. Environmental protection
1. Safetyinstructions
- During the tests, touch the device at the insulated
test probes
9
, and only and do not touch
the bare testing electrodes
8
!
- Check the device for correct functioning immedi-
ately before and after using it (see section 3)! Do
not use the device, if one or more indications are
not working or if it does not seem to be ready for
operation!
- If it is assumed that safe operation is no longer
possible, the device must be switched off immedi-
ately.
- Absolutely prevent the device from getting wet
and avoid any water condensation at the device.
Moreover, the device must be protected against
contamination and damaging!
- The device must be used within the stated nomi-
nal voltage range and in electrical installations of
up to 500 V AC only!
- The device must be used only in electric circuits
of overvoltage category CAT III with max. 300 V
for phase-to-earth measurements. For measure-
ments within measuring category III, the protrud-
ing conductive part of a testing electrode
8
of the
test probe must not be longer than 4 mm. Before
carrying out measurements within measuring cat-
egory III, the enclosed attachable protective caps
marked with CAT III must be pushed onto the test-
ing electrodes
8
for user protection purposes.
- Please observe that work on live parts and elec-
trical components of all kinds is dangerous! Even
low voltages of 30 V AC and 60 V DC may be
dangerous to human life!
- Do not operate the device with the battery com-
partment being open.
- The device is designed for being used by qualified
electricians and under safe working conditions.
- Do not dismantle the device!
Attention!
The device is provided with a high-power LED torch.
Do not look directly or indirectly via reflecting surfaces
into the LED beam. An LED beam might cause irrepa-
rable damage to your eyes.
Symbols on the device:
Symbol Meaning
Attention! Please observe documenta-
tion!
This symbol indicates that the informa-
tion provided in the operating manual
must be complied with in order to avoid
risks.
Alternating voltage (AC)
Earth (voltage to earth)
This symbol shows the orientation of the
batteries for inserting them with correct
polarity.
Warning! Potentially dangerous optical
radiation!
Do not look directly into the light beam!
Danger to your retina!
Attention! Magnets might affect the cor-
rect functioning of cardiac pacemakers
and implanted defibrillators. As a user of
such medical devices, keep a sufficient
distance to the magnet.
2. Device description
1
Red LED for external conductor (phase) L1
2
Red LED for external conductor (phase) L2
3
Red LED for external conductor (phase) L3
4
Red LED for counter-clockwise phase sequence
5
Green LED for clockwise phase sequence
6
High-power LED torch
7
Push-button
8
Testing electrodes with attachable protective caps
9
Test probe L1 (brown), part no.: 10112582
Test probe L2 (black), part no.: 10112581
Test probe L3 (grey), part no.: 10112584
Alligator clip, part no.: 709269
Catch of the battery compartment cover
Battery compartment cover with magnet, belt clip
and technical data
3. Functional test
- Check the device for correct functioning immedi-
ately before and after using it!
- Test the correct functioning of the LEDs
1
,
2
and
3
for indicating the external conductors L1,
L2 and L3 as well as the LEDs
4
and
5
of the
phase sequence indication with a familiar voltage
source, e.g. a 400 V CEE socket.
- Do not use the device, if not all functions are
working properly!
- Please replace the batteries as soon as the lumi-
nosity of the LED torch
6
decreases.
4. Phase sequence test
- Connect the connecting cables marked with L1,
L2 and L3 to the mains to be tested. For this pur-
pose, use the test probes
9
, and or the alli-
gator clip .
- The external conductor voltages are indicated by
means of the red LEDs
1
,
2
and
3
.
- Depending on the connection, the red LED (4) for
"counter-clockwise phase sequence" or the green
LED
5
for "clockwise phase sequence" will be
activated.
- Interchanging the test probes on two external
conductors must result in a change of the phase
sequence.
- For each test, make sure that all three external
conductor voltages are present. Only then, the
indicated results can be analyzed!
5

Hulp nodig? Stel uw vraag in het forum

Spelregels

Misbruik melden

Gebruikershandleiding.com neemt misbruik van zijn services uitermate serieus. U kunt hieronder aangeven waarom deze vraag ongepast is. Wij controleren de vraag en zonodig wordt deze verwijderd.

Product:

Bijvoorbeeld antisemitische inhoud, racistische inhoud, of materiaal dat gewelddadige fysieke handelingen tot gevolg kan hebben.

Bijvoorbeeld een creditcardnummer, een persoonlijk identificatienummer, of een geheim adres. E-mailadressen en volledige namen worden niet als privégegevens beschouwd.

Spelregels forum

Om tot zinvolle vragen te komen hanteren wij de volgende spelregels:

Belangrijk! Als er een antwoord wordt gegeven op uw vraag, dan is het voor de gever van het antwoord nuttig om te weten als u er wel (of niet) mee geholpen bent! Wij vragen u dus ook te reageren op een antwoord.

Belangrijk! Antwoorden worden ook per e-mail naar abonnees gestuurd. Laat uw emailadres achter op deze site, zodat u op de hoogte blijft. U krijgt dan ook andere vragen en antwoorden te zien.

Abonneren

Abonneer u voor het ontvangen van emails voor uw Benning Tritest Pro bij:


U ontvangt een email met instructies om u voor één of beide opties in te schrijven.


Ontvang uw handleiding per email

Vul uw emailadres in en ontvang de handleiding van Benning Tritest Pro in de taal/talen: Nederlands, Duits, Engels, Frans, Italiaans, Spaans, Pools, Turks, Zweeds als bijlage per email.

De handleiding is 1,2 mb groot.

 

U ontvangt de handleiding per email binnen enkele minuten. Als u geen email heeft ontvangen, dan heeft u waarschijnlijk een verkeerd emailadres ingevuld of is uw mailbox te vol. Daarnaast kan het zijn dat uw internetprovider een maximum heeft aan de grootte per email. Omdat hier een handleiding wordt meegestuurd, kan het voorkomen dat de email groter is dan toegestaan bij uw provider.

Stel vragen via chat aan uw handleiding

Stel uw vraag over deze PDF

loading

Uw handleiding is per email verstuurd. Controleer uw email

Als u niet binnen een kwartier uw email met handleiding ontvangen heeft, kan het zijn dat u een verkeerd emailadres heeft ingevuld of dat uw emailprovider een maximum grootte per email heeft ingesteld die kleiner is dan de grootte van de handleiding.

Er is een email naar u verstuurd om uw inschrijving definitief te maken.

Controleer uw email en volg de aanwijzingen op om uw inschrijving definitief te maken

U heeft geen emailadres opgegeven

Als u de handleiding per email wilt ontvangen, vul dan een geldig emailadres in.

Uw vraag is op deze pagina toegevoegd

Wilt u een email ontvangen bij een antwoord en/of nieuwe vragen? Vul dan hier uw emailadres in.



Info