719599
34
Verklein
Vergroot
Pagina terug
1/48
Pagina verder
/ 143
CCA 050 U-I
SCA 070 U-I / SCA 085 U-I / SCA 100 U-I / SCA 135 U-I
UNITÁ INTERNA/ INDOOR UNIT/ UNITE INTERNE/
RAUMGERÄT / INTERNE EENHEID
FUNCTION OF SWITCH
SWITCH
FOR CCM UNIT ADDRESS
0
8
4
1
2
3
5
6
7
C
9
A
B
D
E
F
0~15
S2
+
S1
ADDRESS
ON
1 2
ON
1 2
ON
1 2
ON
1 2
32~47
0
8
4
1
2
3
5
6
7
C
9
A
B
D
E
F
0
8
4
1
2
3
5
6
7
C
9
A
B
D
E
F
16~31
48~63
0
8
4
1
2
3
5
6
7
C
9
A
B
D
E
F
S2
+
S1
ADDRESS
Fa c t or y
Set t i ng
Fa c t or y
Set t i ng
S W IT C H
F OR T E MP.C O M P E N S AT IO N
S W 6
ON
2
ST ATE
VAL UE
4
6
E f u n c tio n
Fa c t or y
Se t t i ng
ON
1 2
ON
1 2
ON
1 2
ON
1 2
S W IT C H
F OR F A N M O TE R
C O NT R O L T H E N N O
P O WE R R E Q U E S T .
S W 2
ST AT E
MODE
FAN OF F
FAN ON
Fa c t or y
Se t t i ng
ON
ON
ON
CN16
CN14
XS9
SWING
MOTOR
XP9
RED
R e a ctor
RED
CN13
DIS P L AY
B O A R D
T O W IR E
C O N T R O L L E R
10
T 2
T 1
C N6
4
ROOM TEMP .
N E W FA N
C N8
M
C N10 A
(C N1 0 )
P UMP
M
2
IN DO O R U N IT
MA IN B O A R D
C N40
T O W IR E
C O N T R O L L E R
5
C N23
O N - O F F
R e mote
C ontrol
C N33
A L A R M
Ala rm
O utput
O uter D river D C M otor
Y /G
D C M O T O R
D R IV E R M O DL E
C N1 3
C N3
3
C N1 5
M
Inne r D river
DC M otor
5
M
R E D (B R O W N )
C N1
B L U E ( B L A C K )
C N5
WATER LEVEL SWITCH
E Y X
To C C M
C omm. B us
C N7
T 2B
OUTER PIPE TEMP .
P 1
C N3
J R 6
J R 6
FAN1
CAP1
Y/G
P3
P2
6
CN4
2
H
C H
P 4
Y /G
4
B R O W N
B L A C K
C N110
Y E L L OW
T O O U T D O O R U N IT
MAGNETIC
RING
MAGNETIC RING
NOTE:
The wiring diagram
is for explanation
purpose only. The
actual shape of the
components may be
dierent.
16022500004023
(INDOOR UNIT)
WIRING DIAGRAM
S W IT C H
F OR C OOL IN G & H E AT I NG
S W 7
ON
ST AT E
MODE
COOLI NG&
HEAT I NG
COOLI NG
ONLY
ON
ON
Fa c t or y
Se t t i ng
O R
S E T T IN G
C O O LIN G O N L Y
8
24
15
FAN MOTOR STOP-TEM
SW1
ON
1 2
ON
1 2
ON
1 2
ON
1 2
Anti-cold air
Ac cording
to the
E E P R O M
s e tting
Factory setting
ON
S W IT C H
F OR A UT O -R E S T A R T
S W 3
ON
STATE
MODE
RE ME MB E R
NO_R EMEMBE R
ON
Fa c t or y
Set t i ng
S E T T IN G
S W IT C H
F OR M O DE -P R IO R S E T T I N G
ON
ST ATE
MODE
HE AT
Fa c t or y
Se t t i ng
ON
1 2
ON
1 2
ON
1 2
ON
1 2
HE AT
COOL
COOL
S W 5
106~140
161~200
0
8
4
1
2
3
5
6
7
C
9
A
B
D
E
F
0
8
4
1
2
3
5
6
7
C
9
A
B
D
E
F
0
8
4
1
2
3
5
6
7
C
9
A
B
D
E
F
0
8
4
1
2
3
5
6
7
C
9
A
B
D
E
F
0
8
4
1
2
3
5
6
7
C
9
A
B
D
E
F
0
8
4
1
2
3
5
6
7
C
9
A
B
D
E
F
0
8
4
1
2
3
5
6
7
C
9
A
B
D
E
F
0
8
4
1
2
3
5
6
7
C
9
A
B
D
E
F
0
8
4
1
2
3
5
6
7
C
9
A
B
D
E
F
0
8
4
1
2
3
5
6
7
C
9
A
B
D
E
F
20
26
36~5332~35 54~71 72~90 91~105 141~160
CN16
CN14
SWING
MOTOR
XS9
XP9
XS10 XP10
FUNCTION OF SWITCH
12000W-14000W(5.0HP)
6
9
8
7
4
5
/
9100W-10500W」ィ4.0HP」ゥ
7500W-9000W 」ィ3.2HP」ゥ
5400W-7100W」ィ2.5HP」ゥ
4000W-5300W」ィ2.0HP」ゥ
NUMBER
SWITCHENC1
(FOR POWER)
POWER
CN55
CN66
TO SWING
BOARD
XS2
XP2
TO GO-UP-AND
-DOWN BOARD
XS2
XP2
SWITCH
FOR TEMP.COMPENSATION
SW6
ON
6
STATE
VALUE
4
2
E function
SWITCH
FOR MAINSLAVE SETTING
SW5
ON
STATE
MODE
MAIN
NO SLAVE
MAIN
MAIN
SLAVE
SWITCH
FOR AUTORESTART SETTING
SW3
ON
STATE
MODE
REMEMBER
NO_REMEMBER
SWITCH
FOR FAN MOTER CONTROL
THEN NO POWER REQUEST.
SW2
ON
STATE
MODE
FAN ON
FAN OFF
8
A
SWITCH
FOR CCM UNIT ADDRESS
RED
Reactor
0
8
4
1
2
3
5
6
7
C
9
A
B
D
E
F
0~15
S2
+
S1
ADDRESS
ON
1 2
ON
1 2
ON
1 2
ON
1 2
Factory
Setting
Factory
Setting
Factory
Setting
32~47
0
8
4
1
2
3
5
6
7
C
9
A
B
D
E
F
0
8
4
1
2
3
5
6
7
C
9
A
B
D
E
F
0
8
4
1
2
3
5
6
7
C
9
A
B
D
E
F
16~31
48~63
S2
+
S1
ADDRESS
Factory
Setting
Factory
Setting
ON
1 2
ON
1 2
ON
1 2
ON
1 2
ON
1 2
ON
1 2
ON
1 2
ON
1 2
ON
ON
ON
ON
RED
Factory
Setting
24
15
FAN MOTOR STOP-TEM
SW1
ON
1 2
ON
1 2
ON
1 2
ON
1 2
Anti-cold air
According
to the
EEPROM
setting
Factory setting
14500W-16000W(6.0HP)
CN13
DISPLAY
BOARD
TO WIRE
CONTROLLER
10
T2
T1
CN6
4
MIDDLE PIPE TEMP.
ROOM TEMP.
BLACK
WHITE
NEWFAN
CN8
M
CN10(CN10A)
M
PUMP
2
INDOOR UNIT
MAINBOARD
CN40
TO WIRE
CONTROLLER
4
CN23
ON - OFF
Remote
Control
CN33
ALARM
Alarm
Output
Outer Driver DC Motor
Y/G
DC MOTOR
DRIVER MODLE
CN13
CN3
3
CN15
M
Inner Driver
DC Motor
5
5
M
RED(BROWN)
CN1
BLUE(BLACK)
L
N
Y/G
CN5
WATER LEVEL SWITCH
CN2
Q E P
To CCM
Comm.Bus
CN7
T2B
OUTER PIPE TEMP.
P1
Y/G
CN3
JR6
JR6
To OUTDOOR
Comm.Bus
FAN1
CAP1
Y/G
P3
CH
P2
H
4
6
CN4
S2
S1
BLACK
BROWN
P4
E Y X
5
L
N
TO OUTDOOR UNIT
L
N
FOR OUTDOOR POWER SUPPLY
POWER
CN1
SWING
MOTOR
MAGNETIC RING
MAGNETIC RING
MAGNETIC RING
- - - - This symbol indicates the
element is optional,the actual
shape shall prevail.
NOTA: COLLEGAMENTI A CURA DELL’INSTALLATORE / NOTE: WIRING TO BE DONE BY THE INSTALLER / REMARQUE: RACCOR-
DEMENTS À LA CHARGE DE L’INSTALLATEUR / HINWEIS: VOM INSTALLATEUR AUSZUFÜHRENDER ANSCHLUSS / OPMERKING:
AANSLUITINGEN UIT TE VOEREN DOOR DE INSTALLATEUR
ATTENZIONE! La posizione dei terminali potrebbe essere dierente / WARNING! The actual shape of the components may be
dierent / ATTENTION! La position des bornes pourrait être diérente / ACHTUNG! Klemmenposition könnte abweichen / LET OP!
De positie van de eindstukken kan verschillen
34

Hulp nodig? Stel uw vraag in het forum

Spelregels

Misbruik melden

Gebruikershandleiding.com neemt misbruik van zijn services uitermate serieus. U kunt hieronder aangeven waarom deze vraag ongepast is. Wij controleren de vraag en zonodig wordt deze verwijderd.

Product:

Bijvoorbeeld antisemitische inhoud, racistische inhoud, of materiaal dat gewelddadige fysieke handelingen tot gevolg kan hebben.

Bijvoorbeeld een creditcardnummer, een persoonlijk identificatienummer, of een geheim adres. E-mailadressen en volledige namen worden niet als privégegevens beschouwd.

Spelregels forum

Om tot zinvolle vragen te komen hanteren wij de volgende spelregels:

Belangrijk! Als er een antwoord wordt gegeven op uw vraag, dan is het voor de gever van het antwoord nuttig om te weten als u er wel (of niet) mee geholpen bent! Wij vragen u dus ook te reageren op een antwoord.

Belangrijk! Antwoorden worden ook per e-mail naar abonnees gestuurd. Laat uw emailadres achter op deze site, zodat u op de hoogte blijft. U krijgt dan ook andere vragen en antwoorden te zien.

Abonneren

Abonneer u voor het ontvangen van emails voor uw Ariston Cassette Compact R32 bij:


U ontvangt een email met instructies om u voor één of beide opties in te schrijven.


Ontvang uw handleiding per email

Vul uw emailadres in en ontvang de handleiding van Ariston Cassette Compact R32 in de taal/talen: Nederlands als bijlage per email.

De handleiding is 3,73 mb groot.

 

U ontvangt de handleiding per email binnen enkele minuten. Als u geen email heeft ontvangen, dan heeft u waarschijnlijk een verkeerd emailadres ingevuld of is uw mailbox te vol. Daarnaast kan het zijn dat uw internetprovider een maximum heeft aan de grootte per email. Omdat hier een handleiding wordt meegestuurd, kan het voorkomen dat de email groter is dan toegestaan bij uw provider.

Stel vragen via chat aan uw handleiding

Stel uw vraag over deze PDF

loading

Andere handleiding(en) van Ariston Cassette Compact R32

Ariston Cassette Compact R32 Gebruiksaanwijzing - Deutsch - 48 pagina's

Ariston Cassette Compact R32 Gebruiksaanwijzing - Français - 48 pagina's


Uw handleiding is per email verstuurd. Controleer uw email

Als u niet binnen een kwartier uw email met handleiding ontvangen heeft, kan het zijn dat u een verkeerd emailadres heeft ingevuld of dat uw emailprovider een maximum grootte per email heeft ingesteld die kleiner is dan de grootte van de handleiding.

Er is een email naar u verstuurd om uw inschrijving definitief te maken.

Controleer uw email en volg de aanwijzingen op om uw inschrijving definitief te maken

U heeft geen emailadres opgegeven

Als u de handleiding per email wilt ontvangen, vul dan een geldig emailadres in.

Uw vraag is op deze pagina toegevoegd

Wilt u een email ontvangen bij een antwoord en/of nieuwe vragen? Vul dan hier uw emailadres in.



Info