ML5000 User Guide 33
F5 G1 TB ENABLE. Press these to enable
talkback to any combination of grp/aux master
outputs. When selected, pressing the TALK TO TB
switch S6 routes the talkback mic signal, or
pressing the OSC/NOISE TO TB switch Q3 routes
the osc/noise generator signal to the output. When
not selected, pressing these switches does not
affect the output. The talkback and osc/noise
signals are routed pre-insert.
F6 G2 MUTE. This momentary action switch
turns the grp/aux master signal on or off. The
master can also be muted by the mute groups, VCA
group mutes, snapshot memories, solo-in-place and
MIDI note on/off messages. The switch illuminates
when the signal is muted.
The switch also functions as a solo select when the
console is in SIP mode, and as an edit key when in
EDIT GROUPS or EDIT SAFES mode. The mute
status is always displayed on the switch regardless
of mode.
F7 G3 SAFE / EDIT. This green LED has a
different function according to console mode:
Normal The LED lights when the master has been
made safe from the snapshot and MIDI automation.
Solo-in-Place The LED lights when the master
has been made safe from solo-in-place.
Edit Safes Indicates that the master is safe from
the automation when entered from normal mode, or
safe from solo-in-place when entered from SIP
mode.
Edit Groups The LED lights to indicate that the
master is assigned to the mute group.
Preview Snapshots The LED lights to indicate
that the master is muted in the snapshot memory
being previewed.
F9 G5 MIX METER. The 5 LED bar meter
displays the post-mute, pre-fade mix signal level.
SIG lights to display signal presence at –26dB, -6, 0
and +6 display normal signal level, and PK (peak)
lights when the signal is within 5dB of clipping. PK
senses the signal pre and post-fader to warn of
potential overload.
If the red PK LED lights check the channels feeding
the mix for correct operating level and reduce the
input level if necessary. You can use VCA groups
to simultaneously control the level of more than one
channel. Also check inserted processing for
correct operating level.
F8 G4 AFL. Press this switch to listen to the
master signal in the headphones or engineers
monitor without affecting the main outputs. The
signal is monitored post-insert, post-fader, pre-mute
so that any adjustments made to the faders or
inserted processing such as EQ can be checked.
The ML5000 intelligent P/AFL system provides the
following operating capabilities:
Mono or stereo AFL. Press a single AFL switch
to listen to that master as a mono signal fed to both
left and right channels of the headphones and local
monitor. Press two related AFL switches together
to listen to a related pair in stereo, ideal when
checking in-ear monitor mixes. The odd number
master is fed to the left channel, even to right.
Latching or momentary action. The switch
provides latching or momentary action depending
on how long it is held down. Press and hold for
longer than 1 second for momentary action.
AFL override monitor. Pressing any master AFL
automatically overrides the currently selected
monitor source. Releasing AFL restores that
selection.
PAFL override AFL. Pressing any channel PAFL
overrides the current AFL selection. Releasing
PAFL restores AFL.
AFL cancel PAFL. Pressing an AFL while one or
more PAFL is selected cancels that PAFL selection
and selects the AFL.
Auto cancel or Add mode. The master section
ADD MODE switch P1 determines if pressing a
channel PAFL cancels or adds to any previous
selection.
Clear all. Pressing the master section CLEAR ALL
switch P3 turns off any PAFL / AFL switches
selected and restores the monitor source.
F10 G6 FADER. A 60mm smooth travel K-
fader is fitted providing +10dB gain above the
nominal 0dB operating position. These faders
control the output level of grp/aux 1-16 and are not
part of the console VCA group system.
F11 G7 IDENT STRIP. Identifies the master
numbers and provides a write-on area. The use of
low adhesion artist or masking tape is
recommended.
33

Hulp nodig? Stel uw vraag in het forum

Spelregels

Misbruik melden

Gebruikershandleiding.com neemt misbruik van zijn services uitermate serieus. U kunt hieronder aangeven waarom deze vraag ongepast is. Wij controleren de vraag en zonodig wordt deze verwijderd.

Product:

Bijvoorbeeld antisemitische inhoud, racistische inhoud, of materiaal dat gewelddadige fysieke handelingen tot gevolg kan hebben.

Bijvoorbeeld een creditcardnummer, een persoonlijk identificatienummer, of een geheim adres. E-mailadressen en volledige namen worden niet als privégegevens beschouwd.

Spelregels forum

Om tot zinvolle vragen te komen hanteren wij de volgende spelregels:

Belangrijk! Als er een antwoord wordt gegeven op uw vraag, dan is het voor de gever van het antwoord nuttig om te weten als u er wel (of niet) mee geholpen bent! Wij vragen u dus ook te reageren op een antwoord.

Belangrijk! Antwoorden worden ook per e-mail naar abonnees gestuurd. Laat uw emailadres achter op deze site, zodat u op de hoogte blijft. U krijgt dan ook andere vragen en antwoorden te zien.

Abonneren

Abonneer u voor het ontvangen van emails voor uw Allen-Heath ML-5000 bij:


U ontvangt een email met instructies om u voor één of beide opties in te schrijven.


Ontvang uw handleiding per email

Vul uw emailadres in en ontvang de handleiding van Allen-Heath ML-5000 in de taal/talen: Engels als bijlage per email.

De handleiding is 3,46 mb groot.

 

U ontvangt de handleiding per email binnen enkele minuten. Als u geen email heeft ontvangen, dan heeft u waarschijnlijk een verkeerd emailadres ingevuld of is uw mailbox te vol. Daarnaast kan het zijn dat uw internetprovider een maximum heeft aan de grootte per email. Omdat hier een handleiding wordt meegestuurd, kan het voorkomen dat de email groter is dan toegestaan bij uw provider.

Stel vragen via chat aan uw handleiding

Stel uw vraag over deze PDF

loading

Uw handleiding is per email verstuurd. Controleer uw email

Als u niet binnen een kwartier uw email met handleiding ontvangen heeft, kan het zijn dat u een verkeerd emailadres heeft ingevuld of dat uw emailprovider een maximum grootte per email heeft ingesteld die kleiner is dan de grootte van de handleiding.

Er is een email naar u verstuurd om uw inschrijving definitief te maken.

Controleer uw email en volg de aanwijzingen op om uw inschrijving definitief te maken

U heeft geen emailadres opgegeven

Als u de handleiding per email wilt ontvangen, vul dan een geldig emailadres in.

Uw vraag is op deze pagina toegevoegd

Wilt u een email ontvangen bij een antwoord en/of nieuwe vragen? Vul dan hier uw emailadres in.



Info