The cooking performance features of the popular and proven
solid fuel Rayburn Cookers have been preserved and
integrated into the Rayburn 300K and Rayburn 308K burning
Commercial Kerosene current issue to BS. 2869 Class C2
suitable for vapourising burners.
The Rayburn 308K provides domestic hot water and cooking
facilities, whereas the Rayburn 300K provides cooking
facilities only, which consists of a heat-graduated hotplate,
main oven and warming oven. The circular oil burner is
controlled by a manually operated oil valve control knob. The
burner should always be continuously burning at low fire rate
when not required for cooking. When cooking is required, the
burner operates at a high fire rate by adjustment of the control
knob and its setting.
NOTE: For safety and reliability, this appliance must be
commissioned by a competent engineer, such as OFTEC
approved.
NOTE: FOR LONG SHUT-DOWN PERIODS, CLOSE ALL
OIL VALVES BETWEEN THE OIL TANK AND THE
APPLIANCE.
WARNING: OIL BURNER: NEVER ATTEMPT TO RELIGHT
A HOT BURNER - DO NOT TURN THE OIL ON UNTIL
BURNER IS COOL.
NOTE: SMOKE/SMELL EMITTED DURING INITIAL USAGE
Some parts of the cooker have been coated with a light
covering of protective oil. During initial operation of the
cooker, this may cause smoke/smell to be emitted and is
normal and not a fault with the appliance, it is therefore
advisable to open doors and or windows to allow for
ventilation. Lift the lids to prevent staining the linings.
WARNING: PLEASE NOTE, DURING USE MANY PARTS
OF THE APPLIANCE CAN BECOME HOT TO TOUCH,
TAKE CARE IF THE ROOM IS USED BY ELDERLY, INFIRM
OR YOUNG PERSONS.
Users Instructions for
Rayburn 300K and
Rayburn 308K
Oil-Fired Cooker
01/10 EOPI 511986raywarranty@aga-web.co.uk 1
INTRODUCTION
IMPORTANT
The cooker burner is intended to run in a
continuously alight condition at all times,
at low fire rate when idling. Turning
the cooker burner OFF
is NOT
recommended unless servicing
is required or when the
cooker is left
unattended
for several
days.
Consumer Protection Act 1987
As responsible manufacturers we take care to make sure that our
products are designed and constructed to meet the required safety
standards when properly installed and used.
IMPORTANT NOTICE: PLEASE READ THE ACCOMPANYING
WARRANTY.
Any alteration that is not approved by Aga could invalidate the
approval of the appliance, operation of the warranty and could affect
your statutory rights.
Control of Substances - Health and Safety
Important
This appliance may contain some of the materials that are indicated.
It is the Users/Installers responsibility to ensure that the necessary
personal protective clothing is worn when handling, where
applicable, the pertinent parts that contain any of the listedmaterials
that could be interpreted as being injurious to health and safety, see
below for information.
Firebricks, Fuel beds, Artificial Fuels - when handling use
disposable gloves.
Fire Cement - when handling use disposable gloves.
Glues and Sealants - exercise caution - if these are still in liquid
form use face mask and disposable gloves.
Glass Yarn, Mineral Wool, Insulation Pads, Ceramic Fibre,
Kerosene Oil - may be harmful if inhaled, may be irritating to skin,
eyes, nose and throat. When handling avoid inhaling and contact
with skin or eyes. Use disposable gloves, face-masks and eye
protection. After handling wash hands and other exposed parts.
When disposing of the product, reduce dust with water spray,
ensure that parts are securely wrapped.
308K OFCERT License No.: 0400040014
300K OFCERT License No.: 0400040013