A100 OPERATING MANUAL
© 2002 Design, 2012 Doc. No. 12-7271-r01 (4/25/12)
Battery Removal
• Remove the Retaining Bar located across the lower portion of the Battery (Fig. 65a).
• Remove the Cover O-ring. DO NOT use tools.
• Slide the Battery up and out of the Battery Compartment.
Inspection
• Closely check all of the sealing surfaces for any signs of damage that might impair proper sealing.
• Inspect the Button, Lens, and Housing to ensure they are not cracked or damaged.


Battery Installation
• Slide a new 3 volt type CR2450 Lithium Battery, ( - ) negative side down into the Battery Compartment. Slide it in from the
right side and ensure that it slides under the contact clip on the left rim (Fig. 66).
• Orient the Retaining Bar across the lower portion of the Battery and carefully push it down into position (Fig. 67).
Battery Cover and Retaining Ring Installation
• Lightly lubricate a new Cover O-ring* with silicone grease and place it on the inner rim of the Battery Cover (Fig. 68).
Ensure that it is evenly seated.
*The O-ring must be a genuine AERIS part that can be purchased from an Authorized AERIS Dealer.
Use of any other O-ring will void the warranty.
• Slide the Cover Ring, top portion first (small opening), onto your thumb.
• Carefully place the Battery Cover (with O-ring) into position on the rim of the Battery Compartment, then press it evenly and
completely down into place with your same thumb.
• Maintain the Battery Cover securely in place and, using your other hand, slide the Cover Ring down off your thumb and into
position around the Battery Compartment.
• The tabs on the Cover Ring fit down into the two slots located at the 2 and 8 o'clock positions.
• Using your fingers, turn the Ring counter clockwise 5 degrees until the tabs engage (Fig. 69), then tighten it 5 more degrees
by turning it counter clockwise with the aide of a small blade screwdriver (Fig. 70).
• While tightening the Retaining Ring, exert continuous inward pressure on it until it is secured in the proper position. A small
symbol located on the Ring should be aligned with the Locked symbol located on the Housing (Fig. 71a).
Inspection
• Activate the unit and watch carefully as it performs a full diagnostic and battery check, and enters Surface Mode.
• Observe the LCD display to ensure it is consistently clear and sharp in contrast throughout the screen.


RETURNING THE MODULE TO BOOT
• If the boot was fitted with a spacer and it was previously removed, replace the spacer into the boot.
• Orient the module over the opening in the boot, and dip the bottom edge into it while pressing the top edge with the palm of
your hand. Stop pressing when the bottom edge of the module has just entered the boot.
• Correct the alignment of the module as needed so that it is straight.
• Press the module completely into place with your thumbs, watching the alignment, until it snaps into place.
ALTITUDE SENSING AND ADJUSTMENT
Altitude (i.e., ambient pressure) is measured upon activation and every 15 minutes until a dive is made.
> Measurements are only taken when the unit is dry.
> Two readings are taken, the second reading 5 seconds after the first. The readings must be within 1 foot (30 cm) of each
other to record that ambient pressure as the current Altitude.
> No adjustments are made during any time that the Wet Contacts are bridged.
> When diving in high altitude waters from 3,001 to 14,000 feet (916 to 4,270 meters), the A100 automatically adjusts to
these conditions providing corrected Depth, and reduced No Deco and O2 Times at intervals of 1,000 feet (305 meters).
> At Sea Level, calculations are based upon an Altitude of 6,000 feet.
> All adjustments for Altitudes greater than 11,000 feet (3,355 meters) are then made to allowable dive times for 14,000 feet
(4,270 meters).
> The A100 will not function as a Dive Computer above 14,000 feet (4,270 meters).
Fig. 69 - TABS ENGAGE
Fig. 70 - TABS TIGHT
Fig. 71 - RING SECURE
a
Fig. 66 - BATTERY
Fig. 67 - RETAINING BAR
Fig. 68 - COVER O-RING
Fig. 65 - RETAINING BAR
a
24

Hulp nodig? Stel uw vraag in het forum

Spelregels

Misbruik melden

Gebruikershandleiding.com neemt misbruik van zijn services uitermate serieus. U kunt hieronder aangeven waarom deze vraag ongepast is. Wij controleren de vraag en zonodig wordt deze verwijderd.

Product:

Bijvoorbeeld antisemitische inhoud, racistische inhoud, of materiaal dat gewelddadige fysieke handelingen tot gevolg kan hebben.

Bijvoorbeeld een creditcardnummer, een persoonlijk identificatienummer, of een geheim adres. E-mailadressen en volledige namen worden niet als privégegevens beschouwd.

Spelregels forum

Om tot zinvolle vragen te komen hanteren wij de volgende spelregels:

Belangrijk! Als er een antwoord wordt gegeven op uw vraag, dan is het voor de gever van het antwoord nuttig om te weten als u er wel (of niet) mee geholpen bent! Wij vragen u dus ook te reageren op een antwoord.

Belangrijk! Antwoorden worden ook per e-mail naar abonnees gestuurd. Laat uw emailadres achter op deze site, zodat u op de hoogte blijft. U krijgt dan ook andere vragen en antwoorden te zien.

Abonneren

Abonneer u voor het ontvangen van emails voor uw Aeris A100 bij:


U ontvangt een email met instructies om u voor één of beide opties in te schrijven.


Ontvang uw handleiding per email

Vul uw emailadres in en ontvang de handleiding van Aeris A100 in de taal/talen: Engels als bijlage per email.

De handleiding is 7,69 mb groot.

 

U ontvangt de handleiding per email binnen enkele minuten. Als u geen email heeft ontvangen, dan heeft u waarschijnlijk een verkeerd emailadres ingevuld of is uw mailbox te vol. Daarnaast kan het zijn dat uw internetprovider een maximum heeft aan de grootte per email. Omdat hier een handleiding wordt meegestuurd, kan het voorkomen dat de email groter is dan toegestaan bij uw provider.

Stel vragen via chat aan uw handleiding

Stel uw vraag over deze PDF

loading

Uw handleiding is per email verstuurd. Controleer uw email

Als u niet binnen een kwartier uw email met handleiding ontvangen heeft, kan het zijn dat u een verkeerd emailadres heeft ingevuld of dat uw emailprovider een maximum grootte per email heeft ingesteld die kleiner is dan de grootte van de handleiding.

Er is een email naar u verstuurd om uw inschrijving definitief te maken.

Controleer uw email en volg de aanwijzingen op om uw inschrijving definitief te maken

U heeft geen emailadres opgegeven

Als u de handleiding per email wilt ontvangen, vul dan een geldig emailadres in.

Uw vraag is op deze pagina toegevoegd

Wilt u een email ontvangen bij een antwoord en/of nieuwe vragen? Vul dan hier uw emailadres in.



Info