45
Your appliance needs air
For safety reasons, minimum ventila-
tionmust be as shown Fig.
Attention: keep ventilation ope-
nings clear of obstruction;
Rehingeing the door
The side at which the door opens can be changed from the right side (fac-
tory adjustment) to the left side, if the installation site requires.
Warning! When changing the side at which the door opens, the appliance
may not be connected to the mains. Remove plug from the mains befo-
rehand.
Procced as follow:
1. Remove the clip-in ventilation
grille (D).
2. Remove the bottom hinge (E) by
unscrewing the two fixing screws
and keep the hinge gasket (x).
3. Slide the door off pin (G);
unscrew pin (G) and refit it on
the opposite side.
4. Remove the two plugs, to reveal
the holes for the hinge pivots,
and remount them on the other
side.
Rear spacers
In the bag with the documentation,
there are two spacers which must be
fitted.
Slacken the screws and insert the
spacer under the screw head, then