IMMEDIATELY NOTIFY YOUR SUPPLIER OF ANY POTENTIAL DEFECTS AND DISCREPANCIES.
9. CHECKING THE PRODUCT.
When choosing the correct position for the fireplace insert, the following
requirements should be taken into consideration:
- The position of the fireplace insert must be approved by the construction supervisor
(chimney foreman).
- A sufficient air supply must be ensured in the room. Burning 1 kg of the wood requires
approximately 12 m3 of air.
- There must not be any electric cables running through the wall or ceiling where the
fireplace insert will be installed.
- The distances from walls and floors as well as distances from electricity cables and
flammable materials in walls and ceilings, e.g. wooden beams, must also be taken into
account.
- The consumer appliance must be positioned on a floor with the respective floor load
capacity.
The fireplace must not be positioned in rooms:
- where there is no air supply for burning
- where flammable and explosive substances or mixtures are processed, stored or produced
- where by the exhaustion of air, the under-pressure originates towards outdoor
environment (ventilators, fume hoods, ventilation and heating equipment,
ventilation driers, etc.)