2005 PrecisionSensor
6050
6052 BP1000, BP1500 VitalScan
6053 BP2550 SensorControl
6054
6054 BP2510 SensorControl
6057 BP2008
6057 BP2008 PrecisionSensor 2005
6057 BP2510, BP2005, SensorControl
6059 BP2590 PrecisionSensor Pro
6071
6073 BP1650, BP1600 VitalScan Plus
6075
6076
6083 BP3510 SensorControl
6084
6085
6085 BP3560, BP3550 SensorControl Easy Click
BP 1750
BP 6000
BP 6100
BP 6200
BP4000
BP4000 ExactFit
BP4010
BP4020
BP4600
BP5000
BP5010
BP5900
BP6000 series
BPW 4100 VitalScan
BPW 4500 - iCheck 7
BPW4300 - VitalScan
BUA 7200 - ActivScan 9
BUA5000 - ExactFit 1
BUA6150 - ExactFit 3
BUA6350 - ExactFit 5 Connect
ExactFit 3
ExactFit 5
ExactFit BP 4900
ExactFit BP 5900
ExactFit Plus
Truescan BPW4100
Truescan Plus BPW4300
Vitalscan BBP2000
Vitalscan BBP2200
Vitalscan Plus BP-1600
Vitalscan Plus BP-1650
Vitalscan Plus BP-1700
Vitalscan Plus BP-1750
-
Pols bloeddruk eter van Braun. Hoe kan ik de batterijen vervangen.? Gesteld op 28-5-2020 om 21:34
Reageer op deze vraag Misbruik melden -
Heb 6026 oorthermometer braun geeft op aan heb er nieuwe batterij ingedaan maar blijft dit doen Gesteld op 27-10-2018 om 11:41
Reageer op deze vraag Misbruik meldenIk bedoel hij geeft lo aan
Waardeer dit antwoord (1) Misbruik melden
Geantwoord op 27-10-2018 om 11:45
-
Wat betekent Error 21 ? Kan het niet vinden in de handleiding. Gesteld op 20-9-2017 om 14:38
Reageer op deze vraag Misbruik meldenHere is the solution for braun 6084 error 21.
Waardeer dit antwoord Misbruik melden
It take some fine mechanical skills, small scewdriver, glue and patience to fix it.
Mine had the same error. I noticed the pump motor was not starting up and error 21 would popup on the screen!
I opened it up by removing 2 screws. Clicked off the front panel and removed 2 other screws are under the LCD. Desolder the speaker wires. Disconnect 1 rubber tube that goes to the pressure sensor and the big white connector and remove the board. Now you see the white pump motor. Unscrew 4 long black scews and pull it apart. Now you see on top of the motor a white unbalanced round wheel. This is the problem! It got stuck! Since it has slide down too far. You can feel it when you try to move it (Braun disgn failure). How To prevent this.. Remove the small white wheel. Glue it back but dont push it too far down. So it can turn freely. Make sure there is no extra glue anywhere and let it dry. You can apply 3v with an external power supply to the motor contacts to test if it works. Put it all together and enjoy your blood pressure. Happy repairing guys! ;)
Geantwoord op 8-1-2018 om 00:26